User Tools

Site Tools


spindle_speed_control_through_-10v_dac_channel_et10

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
spindle_speed_control_through_-10v_dac_channel_et10 [2017/05/22 22:25] skirillovspindle_speed_control_through_-10v_dac_channel_et10 [2017/12/01 00:42] es
Line 1: Line 1:
-==== Spindle Speed control through +\-10V DAC channel (ET10) ====+===== Spindle Speed control through +\-10V DAC channel (ET10) =====
  
  
Line 11: Line 11:
 There are number of ways to access to DAC Offset register. There are number of ways to access to DAC Offset register.
  
-== PLC controller (Hardware) ==+=== PLC controller (Hardware) ===
  
-DAC offset register is mapped to address 0x32 of [[External CNC Variables]] Area.+DAC offset register is mapped to address 0x32 of [[mycnc:extern_variables|Extern CNC Variables]] Area.
 <code c>#define EXT_ET5_DAC_OFFSET 0x32</code> <code c>#define EXT_ET5_DAC_OFFSET 0x32</code>
  
Line 35: Line 35:
 </code> </code>
  
-Another examples with +\-10V DAC programming can be found here - [[plc:plc_examples#Spindle_On_Relay_and_ET10_dac|M03.plc]], [[plc:plc_examples#Spindle_Speed_Control_for_ET10_DAC| SPN.plc]]+Another examples with +\-10V DAC programming can be found here -  
 +[[plc:plc_examples#M03,_Spindle_On,_Relay_and_ET10_DAC|M03.plc]], [[plc:plc_examples#Spindle_Speed_Control_for_ET10_DAC| SPN.plc]]
  
  
spindle_speed_control_through_-10v_dac_channel_et10.txt · Last modified: 2018/08/31 10:00 by skirillov