Line 13: Line 13:
 The fine-tuning is done through the built-in PLC procedures, with the setup described in detail in the [[mycnc:independent_pulse_generator|Independent Pulse Generator]] manual.  The fine-tuning is done through the built-in PLC procedures, with the setup described in detail in the [[mycnc:independent_pulse_generator|Independent Pulse Generator]] manual. 
  
 +In certain profiles (such as the X1366M4E), the MQL functionality is accessible via the main myCNC screen (in the Coordinates section):
 +
 +{{:mycnc:mql-002-main-screen-x1366m4e.png}}
 +
 +This on-screen element displays the current Flood Coolant Rate (global variable #8133). 
 +
 +A series of hotkeys can also be assigned within the myCNC software to quickly control the flood rate. This can be done by going into Settings > Config > Panel/Pendant > Hotkeys, and assigning two new keyboard shortcuts with the following actions:
 +
 +<code>cnc-gvariable-inc-8133</code>
 +
 +and 
 +
 +<code>cnc-gvariable-dec-8133</code>
 +
 +This will allow the user to quickly change the coolant flood rate from their keyboard.
  
 ====MQL Setup in myCNC software==== ====MQL Setup in myCNC software====
Line 18: Line 33:
 <code>This section has been copied from the Independent Pulse Generator manual linked above.</code> <code>This section has been copied from the Independent Pulse Generator manual linked above.</code>
  
-=== Pulse Generator settings in the Software PLC ===+=== Software PLC for MQL ===
 The rate, ratio and acceleration can be set up in the Software PLC, as well as in the User Settings widget (the Step-Dir Coolant Control section).  The rate, ratio and acceleration can be set up in the Software PLC, as well as in the User Settings widget (the Step-Dir Coolant Control section). 
  
Line 38: Line 53:
 ++++ ++++
  
-=== Pulse Generator settings in Hardware PLC ===+=== Hardware PLC for MQL === 
 + 
 +In addition to the software HANDLER_INIT PLC, certain hardware PLC procedures must be changed for the Minimum Quantity Lubrication to be set up.
  
 Function ''coolant_motor_start()'' is added to the ''mill-func.h'' file: Function ''coolant_motor_start()'' is added to the ''mill-func.h'' file:
mycnc/mql.txt · Last modified: 2020/10/08 11:37 by ivan