 **Alarms** **Alarms**
  
-This section allows you to specify the alarm inputs and the response to these sensors. +  * This section allows you to specify the alarm inputs and the response to these sensors. 
-{{:mycnc:imput.png|}} +{{:mycnc:alarms-002-main-window-description.png}} 
-The selected sensor is activated by setting the "V" symbol in the corresponding field. + 
-{{:mycnc:imput3.png|}} +  * The selected sensor is activated by setting the "V" symbol in the corresponding field. 
-The input number on the controller board is set in the corresponding field "Inputs Number" +{{:mycnc:alarms-003-sensor-name.png}} 
-Numbering of inputs can be found in the documentation for the selected window controller. + 
-{{:mycnc:imput4.png|}} +  * The input number on the controller board is set in the corresponding field "Inputs Number"Numbering of inputs can be found in the documentation for the selected window controller. 
-The type of the sensor is specified in the corresponding field "". +{{:mycnc:alarms-004-input-number.png}} 
-There are two types of input sensors. Normally open - the sensor in the rest position has not closed contacts and in the course of operation the sensor contacts are closed. Normally closed - the sensor in the rest position has closed contacts and during the operation, the sensor contacts are opened. + 
-{{:mycnc:imput5.png|}}+  * The type of the sensor is specified in the corresponding field "". There are two types of input sensors. Normally open - the sensor in the rest position has open contacts and in the course of operation the sensor contacts are closed. Normally closed - the sensor in the rest position has closed contacts and during the operation, the sensor contacts are opened. 
 +{{:mycnc:alarms-005-sensor-type.png}} 
 + 
 +* Additionally, the program can launch a Software PLC command when an alarm is triggered, by specifying a Software PLC handler in this next field:  
 +{{:mycnc:alarms-006-soft-plc.png}} 
 +You can read up more on Software PLC programming here: [[plc:plc|PLC]] 
  
 __//Table of alarm sensors//__ __//Table of alarm sensors//__
Line 31: Line 37:
 |Shpindle Driver Ready|The spindle driver is ready for operation. This sensor is usually installed directly in the spindle drive, but it can also be done on its own.| |Shpindle Driver Ready|The spindle driver is ready for operation. This sensor is usually installed directly in the spindle drive, but it can also be done on its own.|
 |Servo Driver(s) Alarm|Accident of any of the drives installed on the machine. As a rule, the signal of an accident is directly the drive of the engine.| |Servo Driver(s) Alarm|Accident of any of the drives installed on the machine. As a rule, the signal of an accident is directly the drive of the engine.|
 +
 +
 +
 +
 +
 +
 +
  
  