User Tools

Site Tools


thc:thc

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
thc:thc [2019/06/14 14:01] ivanthc:thc [2019/06/17 12:38] ivan
Line 2: Line 2:
  
 ==== THC checkup ==== ==== THC checkup ====
 +
 +This article goes through the steps the user may want to take in order to set the variety of THC settings available in myCNC software to suit their Torch Height Control needs. 
  
 ===Initial Setup - Check the ADC channel number=== ===Initial Setup - Check the ADC channel number===
Line 23: Line 25:
  
  
-=== Check THC/PID settings ===+=== Check Additional THC/PID settings ===
 After the initial ADC setup has been completed, more granular THC settings can be adjusted. These are all located in **Settings > Config > Technology > THC** After the initial ADC setup has been completed, more granular THC settings can be adjusted. These are all located in **Settings > Config > Technology > THC**
 {{:thc:thc-setup-002-main-settings-new.png}} {{:thc:thc-setup-002-main-settings-new.png}}
Line 62: Line 64:
 {{:thc:thc-setup-006-max-speed.png}} {{:thc:thc-setup-006-max-speed.png}}
  
-7.  +7. Set the Acceleration RatioIt is set to be 20 by default, thus setting it to 50 as in the example below will make the acceleration ratio 2.5 larger than the defaultfrom 100% to 250%
-<code>"Alarm Arc Voltage difference..." and  +
-"Alarm Arc Voltage Rise" settings help to prevent the torch diving while +
- moving through the cuton low speed corners etc+
  
-However, if the reference voltage is very different from the real measured voltage  +{{:thc:thc-setup-007-acceleration.png}}
-(more than these values), Height control may not start at allYou may want  +
-to temporarily set these values to "1000" to disable this feature and test  +
-the THC.</code>+
  
-<code>THC PI-control ratios may vary depends on a sheet thickness  +8. Set the **THC Low Speed** value. Whenever the speed of the machine will fall lower than this value, the possibility of the arc voltage fluctuating rises greatly. Thus, to prevent the torch from diving, the last height value before the speed goes below your THC Low Speed value is taken and maintained until the speed rises back up again
-and plasma power source type+
  
-The higher the P-ratios absolute values, the higher the Height Control Speed.  +9. Select the Hi/Lo event output port (63 by default). 
-According to our experience, I-ratios should be set to "-2...-6"+ 
 +10. Select the **THC Small Radius** value. THC will be turned OFF when the value of the cut radius is lower than that specified in this field.  
 + 
 +11. Select **Alarm Arc Voltage difference**. This setting helps prevent the torch from diving while moving through the cut, on low speed corners, etc. The Voltage Difference takes the absolute difference value between the real and the reference voltage. In case of a voltage spike, for example due to the metal part being cut off and the material falling to the ground, this stops the THC from trying to adjust for that by diving after a falling part. This value allows for granular control depending on the operator's needs, and should be set depending on the operator setup.  
 + 
 +12. Select **Alarm Arc Voltage Rise**. This setting looks at the rate at which the voltage is changing - thus, if there has been a single rapid spike to a new voltage value, for example, such as after metal warping due to the heat, the machine will temporarily disable THC until the rise (the derivative of the voltage difference) is stable again. This is useful for when Torch Height Control needs to be turned off temporarily, but still function after a voltage spike.  
 + 
 +{{:thc:thc-setup-008-arc-alarm.png}} 
 + 
 +NOTE: If the reference voltage is very different from the real measured voltage (more than these values), Height Control may not start at all. You may want to temporarily set these values to "1000" to disable this feature and test  
 +the THC. 
 + 
 +13. Set the **THC Start Delay**. This sets a value, in seconds, after which THC will begin during the cutting process. During the beginning of the cut, there may be splatter/arc voltage fluctuations which would interfere with THC, so it is often necessary to wait a fraction of a second before turning the THC ON.  
 + 
 +14. Set **THC Restart Delay** to select the value (in seconds) for which to delay the THC after starting it up again to avoid sudden dives.  
 + 
 +15. Set the **THC P- and I- control ratios**. These will vary depending on sheet thickness and the type of plasma power source you are using. The higher the P-ratios absolute values, the higher the Height Control Speed.  
 + 
 +According to our experience, I-ratios should be set around "-2...-6"
 Higher I-ratio values may lead to oscillation during height control.  Higher I-ratio values may lead to oscillation during height control. 
  
 Both P- and I-ratios should be NEGATIVE for Arc Voltage Height Control (as we are trying to inversely compensate for voltage changes).  Both P- and I-ratios should be NEGATIVE for Arc Voltage Height Control (as we are trying to inversely compensate for voltage changes). 
-This means -  
-The higher Arc Voltage (if compare with reference position),  
-The Lower should be Position. 
-</code> 
  
 +{{:thc:thc-setup-009-pi-ratios.png}}
 +
 +16. Set the **THC pre-off** value (in seconds). This allows to turn THC control OFF before the cutting completes (for example, if we know that THC is not required at the very end of the cutting operation). This value can be set to 0 if not required by the user (majority of user cases). 
 +
 +17. Set the **Cutting pre-off** value (in seconds). This allows to stop the cutting some fraction of a second before the machine stops moving at its working speed and may be useful to some users/operators depending on their cutting needs and machine configuration. This value can be set to 0 if not required by the user.
 +
 +18. Select whether you want to accept jog while THC is activated. This allows for jog in the z-axis while THC is on in order to allow the user to lift/lower the torch manually (for example, to inspect it). This field can be set to OFF if the user does not want to be able to accidentally move the torch during the cutting process while the THC is ON.
 +
 +{{:thc:thc-setup-010-accept-jog.png}}
 +
 +19. Select the **THC Jog speed ratio**. This is usually set to be an order of magnitude lower than the working speed, as to not move the torch erratically. 
  
 === Check that the THC is ON === === Check that the THC is ON ===
Line 90: Line 110:
 The next step is to check if THC is ON in the User Settings. The next step is to check if THC is ON in the User Settings.
  
 +It can be a button in User settings of an item in PLC settings. Both settings will turn THC on/off and both represent the same variables - the user can decide which one they want to use out of convenience.
  
-It can be a button in User settings of an item in PLC settings. Both settings will turn THC on/off and both represent the same variables - the user can decide which one they want to use. +{{:thc:thc-setup-user-settings-001.png}}
-{{hardware:thc:mycnc-thc-009.png}} +
-{{hardware:thc:mycnc-thc-010.png}}+
  
-=== Check that the THC working ===+{{:thc:thc-setup-user-settings-002.png}} 
 + 
 +=== Check that the THC is working ===
  
 Turn THC ON in User settings and make a test cut. Turn THC ON in User settings and make a test cut.
  
   - Check that the "Arc Ref" voltage is about the same as the measured "Arc Voltage" \\ \\ {{hardware:thc:mycnc-thc-014.png}} \\ \\    - Check that the "Arc Ref" voltage is about the same as the measured "Arc Voltage" \\ \\ {{hardware:thc:mycnc-thc-014.png}} \\ \\ 
-  - Check "THC Low Speed" led is OFF \\ \\ {{hardware:thc:mycnc-thc-015.png}} \\ \\ +  - Check that the "THC Low Speed" led is OFF \\ \\ {{hardware:thc:mycnc-thc-015.png}} \\ \\ 
   - "THC Speed" display should show the current Height Control Speed. The current implementation takes the display speed to be in internal machine units, so the absolute "THC Speed" value might not correspond to the actual physical speed of the machine. However, this is still useful since you can see the following:   - "THC Speed" display should show the current Height Control Speed. The current implementation takes the display speed to be in internal machine units, so the absolute "THC Speed" value might not correspond to the actual physical speed of the machine. However, this is still useful since you can see the following:
     - "THC Speed = 0" means THC is off \\ \\ {{hardware:thc:mycnc-thc-016.png}} \\ \\     - "THC Speed = 0" means THC is off \\ \\ {{hardware:thc:mycnc-thc-016.png}} \\ \\
Line 106: Line 127:
     - "THC Speed" is negative - Height Control moves torch DOWN, usually because the Arc Voltage (and the current height) is higher than reference value \\ \\ {{hardware:thc:mycnc-thc-018.png}} \\ \\     - "THC Speed" is negative - Height Control moves torch DOWN, usually because the Arc Voltage (and the current height) is higher than reference value \\ \\ {{hardware:thc:mycnc-thc-018.png}} \\ \\
  
 +===Check Additional User Settings===
 +
 +The **Arc Voltage Control** setting signifies the THC behaviour that the user prefers. 
 +
 +{{:thc:thc-setup-user-settings-003.png}}
 +
 +It can be set up to be **THC OFF**, **Table**, **_Table**, **Measure** and **_Measure**. The Table entries signify that the THC control will be referencing an internal table value for the reference arc voltage, while the Measure entries signify that the Arc Voltage will be measured by the operator and adjusted manually (usually for better granular control). The underscores signify whether or not the Torch Height Control will have a THC Start Delay (the entries with underscores do have the start delay, while the entries without the underscores do not).
 +
 +**Creep Speed** can be set up in order to signify the speed during the creep phase of the machine movement. The Creep speed is set on the CNC Speeds screen as a percentage of the Cut Speed. This setting can help improve the initial plasma arc stability, especially when cutting thick materials. Set the **Creep Time** (in seconds) to signify the length for which the Creep Speed will be active, or set it to 0 to disable Creep Speed. 
 +
 +{{:thc:thc-setup-user-settings-004.png}}
  
 ==== Registers to control THC ==== ==== Registers to control THC ====