User Tools

Site Tools


quickstart:mycnc-quick-start:probe_setup

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
quickstart:mycnc-quick-start:probe_setup [2019/07/04 10:51] ivanquickstart:mycnc-quick-start:probe_setup [2019/07/04 11:40] ivan
Line 3: Line 3:
 The probe tool is currently being sold as part of some myCNC kits. The main sensor looks like the image below: The probe tool is currently being sold as part of some myCNC kits. The main sensor looks like the image below:
  
-{{:quickstart:mycnc-quick-start:vers-pr-render-s-001.jpg}}+{{:quickstart:mycnc-quick-start:sen-prb-wr01-002-small2.jpg}}
  
 This manual covers the basic setup of the probe that can be used in a number of myCNC profiles and applications in order to determine an exact position of the part on a milling machine. The probe can find edges, corners, hole centers, and more.  This manual covers the basic setup of the probe that can be used in a number of myCNC profiles and applications in order to determine an exact position of the part on a milling machine. The probe can find edges, corners, hole centers, and more. 
Line 9: Line 9:
 ====Calibration/Adjustment of the probe sensor==== ====Calibration/Adjustment of the probe sensor====
  
-In order to properly adjust the probe before starting the measurement procedure, it is necessary to eliminate any deviation that might be otherwise present in the probe. For this purpose, an indicator is used, as shown in the image below. This indicator should be sensitive to small forces of about 0.3-0.5 Newtons+In order to properly adjust the probe before starting the measurement procedure, it is necessary to eliminate any deviation that might be otherwise present in the probe. For this purpose, an indicator is used, as shown in the image below. This indicator should be sensitive to small forces of about 0.3-0.5H
  
 {{:quickstart:mycnc-quick-start:probe-calibration-001-indicator-s.jpg}} {{:quickstart:mycnc-quick-start:probe-calibration-001-indicator-s.jpg}}
Line 15: Line 15:
 The spindle axis is moved by hand, and the amplitude of the sensor deviation is recorded using the indicator.  The spindle axis is moved by hand, and the amplitude of the sensor deviation is recorded using the indicator. 
  
-The deviation is eliminated by turning the M2.5 adjustment screws with the 2mm hex key included in the probe kit: +The deviation is eliminated by turning the M2.5 adjustment screws (shown in the image below) with the 2mm hex key provided in the probe kit: 
  
 {{:quickstart:mycnc-quick-start:probe-calibration-002.jpg}} {{:quickstart:mycnc-quick-start:probe-calibration-002.jpg}}
  
-It is recommended to hold the key by short leveras to prevent excessive force application. It might be necessary to perform several cycles of spindle calibration to adjust the probe to have the minimum acceptable deviation. +It is recommended to hold the hex key by its short lever as shown in the image below, in order to prevent excessive force application. It might be necessary to perform several cycles of spindle calibration to adjust the probe to have the minimum acceptable deviation. 
  
 {{:quickstart:mycnc-quick-start:probe-calibration-003-s.jpg}} {{:quickstart:mycnc-quick-start:probe-calibration-003-s.jpg}}
quickstart/mycnc-quick-start/probe_setup.txt · Last modified: 2021/08/04 14:18 by ivan

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki