User Tools

Site Tools


quickstart:mycnc-quick-start:oxyfuel-setup

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
quickstart:mycnc-quick-start:oxyfuel-setup [2019/06/21 12:24] ivanquickstart:mycnc-quick-start:oxyfuel-setup [2021/08/09 14:21] (current) ivan
Line 2: Line 2:
  
 This article introduces the reader to the basics of oxy-fuel (gas) cutting setup using myCNC software. This article introduces the reader to the basics of oxy-fuel (gas) cutting setup using myCNC software.
 +
 +The profile screen description for the oxy-fuel cutting profiles (X1366G/X1366GA) is available here: [[mycnc:mycnc_setup_examples:gas_cutting|Basic profile for Gas Cutting.]]
  
 Upon opening the 1366G profile (gas cutting/welding profile) and navigating to the User Settings, the operator is presented with the following window: Upon opening the 1366G profile (gas cutting/welding profile) and navigating to the User Settings, the operator is presented with the following window:
Line 43: Line 45:
 On most machines, THC and IHC are usually not required for the operator, so these should be turned off by default: On most machines, THC and IHC are usually not required for the operator, so these should be turned off by default:
 {{:quickstart:mycnc-quick-start:oxyfuel-quickstart-thc-002.png}} {{:quickstart:mycnc-quick-start:oxyfuel-quickstart-thc-002.png}}
 +
 +====Start/Stop Setup====
 +
 +For proper oxyfuel cutting start, it is necessary to set the **Direct Move** option in Start/Stop settings. Failure to do so may result in incorrect behaviour for certain procedures, such as Cutting from Edge: 
 +
 +{{:examples:plasma-oxyfuel-setup-003-direct-move.jpg}}
  
 ====Controller Output Connections==== ====Controller Output Connections====
quickstart/mycnc-quick-start/oxyfuel-setup.1561134275.txt.gz · Last modified: 2019/06/21 12:24 by ivan