quickstart:mycnc-quick-start:oxyfuel-setup [2019/06/21 11:41] ivanquickstart:mycnc-quick-start:oxyfuel-setup [2019/06/21 12:24] ivan
Line 59: Line 59:
 |OUT10|Ignition (spark)| |OUT10|Ignition (spark)|
  
-Note that every one of these outputs can be reconfigured if the user so desires. However, in this default configuration, connecting the controller to the machine looks as follows:+Every one of these outputs can be reconfigured if the user so desires. However, in this default configuration, connecting the controller to the machine looks as follows:
  
 {{:quickstart:mycnc-quick-start:oxyfuel-quickstart-008-et7connection.png}} {{:quickstart:mycnc-quick-start:oxyfuel-quickstart-008-et7connection.png}}
 +
 +==Simpler Controller Connections==
 +
 +Note that the image above refers to a full configuration for an oxy-fuel cutting machine equipped with all the possible oxygen flows as well as an ignition cycle. A simpler machine connection configuration with only one pressure of cutting and heating oxygen, a fuel supply and no ignition torch will look as follows:
 +
 +{{:quickstart:mycnc-quick-start:oxyfuel-quickstart-008-et7connection2.png}}
 +