//OC low// is the low-pressure cutting oxygen flow. It is started slightly before the //OC high// (high-pressure cutting oxygen) flow as to prevent the heated metal from splashing onto the torch. Note that if only one cutting oxygen flow is available, //OC low// connection should be used when setting up the machine. | //OC low// is the low-pressure cutting oxygen flow. It is started slightly before the //OC high// (high-pressure cutting oxygen) flow as to prevent the heated metal from splashing onto the torch. Note that if only one cutting oxygen flow is available, //OC low// connection should be used when setting up the machine. | ||
+ | ===THC and IHC=== | ||
+ | |||
+ | On most machines, THC and IHC are usually not required for the operator, so these should be turned off by default: | ||
+ | {{: | ||
====Controller Output Connections==== | ====Controller Output Connections==== | ||
- | In order to check the proper output connections for connecting the controller to the machine setup, go to **Settings > PLC > Hardware PLC > pins.h**. The screen presented to you will be the one below: | + | In order to check the proper output connections for connecting the controller to the machine setup, go to **Settings > PLC > Hardware PLC > pins.h**. The current output configuration can be found on the screen |
- | {{: | + | {{: |
As can be seen here, the following outputs are currently assigned: | As can be seen here, the following outputs are currently assigned: | ||
Line 55: | Line 59: | ||
|OUT10|Ignition (spark)| | |OUT10|Ignition (spark)| | ||
- | Note that every one of these outputs can be reconfigured if the user so desires. However, in this default configuration, | + | Every one of these outputs can be reconfigured if the user so desires. However, in this default configuration, |
{{: | {{: | ||
+ | |||
+ | ==Simpler Controller Connections== | ||
+ | |||
+ | Note that the image above refers to a full configuration for an oxy-fuel cutting machine equipped with all the possible oxygen flows as well as an ignition cycle. A simpler machine connection configuration with only one pressure of cutting and heating oxygen, a fuel supply and no ignition torch will look as follows: | ||
+ | |||
+ | {{: | ||
+ |