mycnc:rtcp_setup [2018/03/24 18:32] skirillovmycnc:rtcp_setup [2018/03/24 18:34] skirillov
Line 9: Line 9:
 Writing "0" to the register will disable RTCP correction.  Writing "0" to the register will disable RTCP correction. 
  
-Switching RTCP Enable/Disable should be done in the vertical position (A=0, B=0) only when real machine position with and without RTCP correction is the same. In this case, machine position will not be changed while RTCP switching.+Switching RTCP Enable/Disable should be done in the vertical position (A=0, B=0) only. Real machine position with and without RTCP correction is the same for vertical. In this case, machine position will not be changed while RTCP switching.
  
 We used M101.plc procedure to disable(off) RTCP correction We used M101.plc procedure to disable(off) RTCP correction
Line 70: Line 70:
 G53 G90 G28.5 Z0 F#100 (move down to saved Z/Register1.Z) G53 G90 G28.5 Z0 F#100 (move down to saved Z/Register1.Z)
  
-M102 (Turn ON RTCP Algorithm #2)+M102 (Turn ON RTCP Correction)
  
 </code> </code>
  
  