User Tools

Site Tools


mycnc:rtcp_setup

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
mycnc:rtcp_setup [2018/03/24 18:32] skirillovmycnc:rtcp_setup [2018/03/24 18:33] skirillov
Line 9: Line 9:
 Writing "0" to the register will disable RTCP correction.  Writing "0" to the register will disable RTCP correction. 
  
-Switching RTCP Enable/Disable should be done in the vertical position (A=0, B=0) only when real machine position with and without RTCP correction is the same. In this case, machine position will not be changed while RTCP switching.+Switching RTCP Enable/Disable should be done in the vertical position (A=0, B=0) only. Real machine position with and without RTCP correction is the same for vertical. In this case, machine position will not be changed while RTCP switching.
  
 We used M101.plc procedure to disable(off) RTCP correction We used M101.plc procedure to disable(off) RTCP correction
mycnc/rtcp_setup.txt · Last modified: 2023/09/29 14:17 by ivan

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki