User Tools

Site Tools


mycnc:mycnc_et7

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
mycnc:mycnc_et7 [2019/06/10 14:02] ivanmycnc:mycnc_et7 [2019/09/20 12:26] ivan
Line 148: Line 148:
 {{hardware:et7:et7-rs485.png}} {{hardware:et7:et7-rs485.png}}
  
-RS422 connector pinout shown below +RS422 connector pinout shown below. **NOTE**: While all of the RX/TX ports (RX A, RX B, TX A, TX B) are used for the RS422 connection (such as a Hypertherm machine), only RX A and RX B are utilized in an RS485 configuration.  
-{{:hardware:et7:et7-b-rs422-connection-001.jpg}}+ 
 +{{:mycnc:et7-b-rs422-connection-002-rs485-connections.jpg}} 
  
 ==== DAC output ==== ==== DAC output ====
Line 161: Line 163:
  
 ==== Connection Examples ==== ==== Connection Examples ====
-=== 3-wire NPN sensor connection example === 
  
-<code>Jumpers J1,J2,J3,J4 are all open.</code> +===Stepper driver connection (4 axes)=== 
-{{:hardware:et7:et7-npn-sensor-002.jpg}}+ 
 +{{:mycnc:et7-stepper-driver-001.jpg}}
  
-=== 3-wire PNP sensor connection example ===+=== 3-wire NPN sensor connection example (external power supply)===
  
 <code>Jumpers J1,J2,J3,J4 are all open.</code> <code>Jumpers J1,J2,J3,J4 are all open.</code>
 +{{:mycnc:et7-npn-external-001-v2.png}}
 +=== 3-wire PNP sensor connection example (external power supply) ===
  
-{{:hardware:et7:et7-pnp-sensor-002.jpg}} +<code>Jumpers J1,J2,J3,J4 are all open.</code> 
 +{{:mycnc:et7-pnp-external-001-v2.png}}
 {{hardware:et7-b-connection-inputs-004.png}} {{hardware:et7-b-connection-inputs-004.png}}
  
Line 179: Line 183:
 One of jumpers J1,J2,J3,J4 (J4 in case of this example) is closed.</code> One of jumpers J1,J2,J3,J4 (J4 in case of this example) is closed.</code>
  
-{{:mycnc:et7-npn-sensor-internal-with-jumpers.png}}+{{:mycnc:et7-npn-internal-001-v2.png}}
  
 === 3-wire PNP sensor connection example (internal power supply)=== === 3-wire PNP sensor connection example (internal power supply)===
Line 186: Line 190:
 All of jumpers J1,J2,J3,J4 are open.</code> All of jumpers J1,J2,J3,J4 are open.</code>
  
-{{:mycnc:et7-pnp-sensor-internal-no-jumpers.png}}+{{:mycnc:et7-pnp-internal-001-v2.png}}
  
 As the sensor requires a 24V power supply, it is necessary to connect it to the 24V port, not the 5V.  As the sensor requires a 24V power supply, it is necessary to connect it to the 24V port, not the 5V. 
Line 200: Line 204:
 Switch should also short the wire to GNC(0V). Switch should also short the wire to GNC(0V).
  
-{{:hardware:et7:et7-switch-connection-001.jpg}}+{{:mycnc:et7-switch-internal-001-v2.png}}
  
 ===Switch connection example (external power supply)=== ===Switch connection example (external power supply)===
  
-{{:mycnc:et7-switch-connection-002-external.png}}+{{:mycnc:et7-switch-external-002-v2.png}}
  
-{{:mycnc:et7-switch-connection-003-external.png}}+{{:mycnc:et7-switch-external-001-v2.png}}
  
 <code>Jumpers J1, J2, J3, J4 are all open</code> <code>Jumpers J1, J2, J3, J4 are all open</code>
Line 280: Line 284:
  
  
 +==== ET7 firmware reflash ====
 +
 +myCNC-ET7 reflashing procedure may take up to 3 minutes.
 +
 +To reflash the board:
 +
 +1. Plug in the 24V DC power supply
 +
 +2. Plug in the micro-USB cable into the ET7 controller & a Host Computer with myCNC installed
 +
 +3. Close jumpers J5(reset) & J6(programming) on the controller board
 +
 +4. Open (remove) the J5 jumper.
 +
 +{{:mycnc:et7-reflash-001.png}}
 +
 +5. Open myCNC software on Host computer (Settings > Support Tab)
 +
 +6. "Select board" set to "myCNC-ET7"
 +
 +7. Select "Firmware version" from "Release", "Night build" or "Testing" ("Release" is recommended)
 +
 +8. "UART port" - select the port with FT232 attached. If no such port visible, check the micro-USB connection, then close and open the Support tab once again in order to refresh it. 
 +
 +9. Baud Rate set to "115200" for ET7; other baudrate can be selected in case of problems on the 115200 speed
 +
 +10. Press "Update Firmware" button, Firmware download and reflashing process will be started
 +
 +11. If "Sector 0; +" message is shown in the debug window, the reflashing process has been finished successfully.
 +
 +12. Remove all jumpers (J4, J5) and restart the board.
 +  
 +{{:mycnc:et7-reflash-002-support.png}}
 +
 +{{:mycnc:et7-reflash-004-success.png}}
  
 +If the reflashing process failed, please check your internet connection and the micro-USB connection, and then repeat the reflashing procedure from Step 3.
mycnc/mycnc_et7.txt · Last modified: 2024/02/28 15:29 by ivan