 ==== ET10 Firmware Reflash ==== ==== ET10 Firmware Reflash ====
 +
 +
 To reflash the board To reflash the board
  
-1. Unplug 24V DC power supply and detach ET10 controller from Breakout board+{{:mycnc:et10-firmware-reflash-002.jpg}} 
 + 
 +1. Unplug the  24V DC power supply and detach the ET10 controller from the Breakout board 
 2. Plug 24V DC supply 2. Plug 24V DC supply
 +
 3. Short power cable between ET1 and Breakout leave connected. 3. Short power cable between ET1 and Breakout leave connected.
-4. Plugin mini-USB cable to ET10 & Host Computer with myCNC installed+ 
 +4. Plug in the mini-USB cable to ET10 & Host Computer with myCNC installed 
 5. Close jumpers J4(reset) & J5)programming) on myCNC controller board 5. Close jumpers J4(reset) & J5)programming) on myCNC controller board
 +
 6. Open(remove) J4(reset) jumper. 6. Open(remove) J4(reset) jumper.
 +
 7. Open myCNC software on Host computer, then go to Settings >  Support Tab 7. Open myCNC software on Host computer, then go to Settings >  Support Tab
 +
 8. "Select board" set to "myCNC-ET10" 8. "Select board" set to "myCNC-ET10"
 +
 9. Select "Firmware version" from "Release", "Night build" or "Testing" 9. Select "Firmware version" from "Release", "Night build" or "Testing"
 +
 10. "UART port" select port with FT232 attached 10. "UART port" select port with FT232 attached
 +
 11. Baud Rate set to "115200" for ET10; other baudrate can be selected in case of problems on 115200 speed 11. Baud Rate set to "115200" for ET10; other baudrate can be selected in case of problems on 115200 speed
 +
 12. Press "Update Firmware" button, Firmware download and reflashing process will be started. 12. Press "Update Firmware" button, Firmware download and reflashing process will be started.
-13. Sector 0 will be written at the end of process, so message in debug window "Sector 0; +" means reflashing process finished successfully.+ 
 +13. Sector 0 will be written at the end of process, so message in debug window "Sector 0; +" means reflashing process finished  
 +successfully. 
 14. Remove all jumpers (J4, J5), assemble TE10 and Breakout and restart the board. 14. Remove all jumpers (J4, J5), assemble TE10 and Breakout and restart the board.
  