User Tools

Site Tools


mycnc:mycnc_et10

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
mycnc:mycnc_et10 [2019/06/10 13:27] ivanmycnc:mycnc_et10 [2019/06/14 13:38] ivan
Line 65: Line 65:
 <code>External power supply. Jumpers are open.</code> <code>External power supply. Jumpers are open.</code>
  
-{{:hardware:et10:et10-connection-inputs-002-key-05-npn-v3.jpg}}+{{:mycnc:et10-npn-external-001-v2.png}}
  
  
Line 72: Line 72:
 <code>External power supply. Jumpers are open.</code> <code>External power supply. Jumpers are open.</code>
  
-{{:hardware:et10:et10-connection-inputs-002-key-06-pnp-v3.jpg}}+{{:mycnc:et10-pnp-external-001-v2.png}}
  
 === 3-wire NPN sensor connection example (internal power supply)=== === 3-wire NPN sensor connection example (internal power supply)===
Line 78: Line 78:
 <code>Internal power supply. Jumpers are open.</code> <code>Internal power supply. Jumpers are open.</code>
  
-{{:mycnc:et10-connection-npn-internal-no-jumper.png}}+{{:mycnc:et10-npn-internal-001-v2.png}}}}
  
 === 3-wire PNP sensor connection example (internal power supply)=== === 3-wire PNP sensor connection example (internal power supply)===
Line 84: Line 84:
 <code>Internal power supply. Jumpers are CLOSED.</code> <code>Internal power supply. Jumpers are CLOSED.</code>
  
-{{:mycnc:et10-connection-pnp-internal-with-jumpers.png}}+{{:mycnc:et10-pnp-internal-001-v2.png}}
  
-=== Switch connection example (external power supply)===+=== Switch connection example===
  
-  * Internal power supply <code>Jumpers for selected group are  closed.</code> {{:mycnc:et10-switch-internal-power-supply.png}} \\ \\ Common wire for 4 optocoupler units is connected to internal GND (0V) if the Jumper is closed. A switch should short another optocoupler input to +24V to activate input pin. \\ \\ Jumper should be closed to connect the optocoupler pin to +24V. A switch should short wire to GND(0V). +  * Internal power supply <code>Jumpers for selected group are  closed.</code> {{:mycnc:et10-switch-internal-001-v2.png}} \\ \\ Common wire for 4 optocoupler units is connected to internal GND (0V) if the Jumper is closed. A switch should short another optocoupler input to +24V to activate input pin. \\ \\ Jumper should be closed to connect the optocoupler pin to +24V. A switch should short wire to GND(0V). 
-  * External power supply (#1) <code>JUMPERS ARE OPEN</code> {{:hardware:et10:et10-connection-inputs-002-key-01-v3.jpg}} +  * External power supply (#1) <code>JUMPERS ARE OPEN</code> {{:mycnc:et10-switch-external-001-v2.png}} 
-  * External power supply (#2) <code>JUMPERS ARE OPEN</code> {{:hardware:et10:et10-connection-inputs-002-key-02-v3.jpg}}+  * External power supply (#2) <code>JUMPERS ARE OPEN</code> {{:mycnc:et10-switch-external-002-v2.png}}
  
 ==== ET10 Encoder inputs ==== ==== ET10 Encoder inputs ====
mycnc/mycnc_et10.txt · Last modified: 2023/10/25 12:59 by ivan

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki