User Tools

Site Tools


mycnc:mycnc_et10

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
mycnc:mycnc_et10 [2019/06/10 13:27] ivanmycnc:mycnc_et10 [2019/06/14 12:52] ivan
Line 65: Line 65:
 <code>External power supply. Jumpers are open.</code> <code>External power supply. Jumpers are open.</code>
  
-{{:hardware:et10:et10-connection-inputs-002-key-05-npn-v3.jpg}}+{{:mycnc:et10-npn-external-001-v2.png}}
  
  
Line 72: Line 72:
 <code>External power supply. Jumpers are open.</code> <code>External power supply. Jumpers are open.</code>
  
-{{:hardware:et10:et10-connection-inputs-002-key-06-pnp-v3.jpg}}+{{:mycnc:et10-pnp-external-001-v2.png}}
  
 === 3-wire NPN sensor connection example (internal power supply)=== === 3-wire NPN sensor connection example (internal power supply)===
Line 78: Line 78:
 <code>Internal power supply. Jumpers are open.</code> <code>Internal power supply. Jumpers are open.</code>
  
-{{:mycnc:et10-connection-npn-internal-no-jumper.png}}+{{:mycnc:et10-npn-internal-001-v2.png}}
  
 === 3-wire PNP sensor connection example (internal power supply)=== === 3-wire PNP sensor connection example (internal power supply)===
Line 84: Line 84:
 <code>Internal power supply. Jumpers are CLOSED.</code> <code>Internal power supply. Jumpers are CLOSED.</code>
  
-{{:mycnc:et10-connection-pnp-internal-with-jumpers.png}}+{{:mycnc:et10-pnp-internal-001-v2.png}}
  
-=== Switch connection example (external power supply)===+=== Switch connection example===
  
-  * Internal power supply <code>Jumpers for selected group are  closed.</code> {{:mycnc:et10-switch-internal-power-supply.png}} \\ \\ Common wire for 4 optocoupler units is connected to internal GND (0V) if the Jumper is closed. A switch should short another optocoupler input to +24V to activate input pin. \\ \\ Jumper should be closed to connect the optocoupler pin to +24V. A switch should short wire to GND(0V). +  * Internal power supply <code>Jumpers for selected group are  closed.</code> {{:mycnc:et10-switch-internal-001-v2.png}} \\ \\ Common wire for 4 optocoupler units is connected to internal GND (0V) if the Jumper is closed. A switch should short another optocoupler input to +24V to activate input pin. \\ \\ Jumper should be closed to connect the optocoupler pin to +24V. A switch should short wire to GND(0V). 
-  * External power supply (#1) <code>JUMPERS ARE OPEN</code> {{:hardware:et10:et10-connection-inputs-002-key-01-v3.jpg}} +  * External power supply (#1) <code>JUMPERS ARE OPEN</code> {{:mycnc:et10-switch-external-001-v2.png}} 
-  * External power supply (#2) <code>JUMPERS ARE OPEN</code> {{:hardware:et10:et10-connection-inputs-002-key-02-v3.jpg}}+  * External power supply (#2) <code>JUMPERS ARE OPEN</code> {{:mycnc:et10-switch-external-002-v2.png}}
  
 ==== ET10 Encoder inputs ==== ==== ET10 Encoder inputs ====
mycnc/mycnc_et10.txt · Last modified: 2023/10/25 12:59 by ivan

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki